(20.30 € HT)
"OVAL" TH thermostatic head with liquid sensor PETTINAROLI reference 107L
Features:
Hysteresis: 0.4°K (107l)
Maximum operating pressure: 10 bar
Maximum differential pressure: 0.8 bar
Maximum test pressure: 16 bar
Maximum fluid temperature: 110°c
Fluid temperature influence: < 0.8°K
Differential pressure influence: 0.8°K
Adjustment range: 5°c - 28°c
Reaction time: 30 min
Fluid temperature influence: 1°K (107l)
Description:
The thermostatic tap must measure the ambient temperature by comparing it to the required temperature in order to adjust the heat supply from the radiator by modifying the tap opening. The ambient temperature acts on a bulb made of a metal bellows containing liquid and saturated vapor (art. 107L) or wax (art. 106CN). This mixture is sensitive to the slightest temperature variation.
It causes a deformation of the bellows that modifies the tap opening. An increase in temperature causes the bulb to expand and thus closes the tap. The proportional band Xp defines the thermal jump between the requested temperature and the ambient temperature to achieve full opening and closing of the tap. The speed of this process depends on the nature of the installation.
The accuracy depends on the hysteresis.